G-Logo


Ex PC-Workstations, Ex-PCs

Ex Automation technology

Ex-p Pressurized enclosures


D122.A D122.PA D122.Z DM110 TA125
DM110BlockdiagramDimensionsPropertiesTech.dataType.codeDownload

Revolution counter DM110 - Technical details

   DM110
General Mounting Inside hazardous area
 Device group II 2 G
 Ex- protection II 2 G Ex q ib IIC T6
 EG- Baumuster TÜV 03 ATEX 2090
 Ambient temperature 10° C ... +50° C at T6
-10° C ... +65° C at T5
 Humidity 5-95%, non-condensing
Housing Type according to DIN 43700
DM 110.0/1: H x W x D = 48 x 96 x 109 mm
DM 110.3/4: H x W x D = 72 x 114 x 116 mm,
DM 110.5/6: H x W x D = 193 x 134 x 82 mm
 Material Noryl DM 110.0-4 . ABS DM 110.5/6
 Protection lass DM110.5/6: IP 65
DM110.0-4: Front up to IP 55
Electrical specifications Circuit limits Uo<= 65 V, Ik <=160 mA
Li and Ci are negligible
 Power cunsumption < 0,1 mA bei 8 V /< 0,3 mA bei 3 V
 Control circuit Intrinsically safe (NAMUR / DIN 19234)
 Measure error < 0,2 % ± 3 Digits
 Temp. Coeffizient < 0,02 %/K
Display Display 4 1/2- LCD-Display
 Figure height DM 110.3/4/5/6: 20,5 mm,
DM 110.0/1: 13,6 mm
 Range 19999
 Dezimalpoint programmable via Dil- switch
 max. frequency 5000 Hz
Option Multiplier- module offers the possibility to multiply the impulses of the measuring sensor according to a programmable factor
Option Supply- module Internal barrier for Ex i- energy
  last modified: 26.10.2011